K Factor Calculator – GF Piping Systems, Compare Flow of K-Factors with New Calculator, Compare Flow of K-Factors with New Calculator, Pipe Flow Expert Sprinkler K Factors, GF Signet publishes K-Factors for water only in gallons (pulses per gallon) and liters (pulses per liter) for all flow sensors, in all applicable pipe sizes and materials, and/or in all applicable installation fitting sizes and materials. Please contact GF Piping Systems Japan for JIS K-Factors.
GF Signet publishes K-Factors for water only in gallons (pulses per gallon) and liters (pulses per liter) for all flow sensors, in all applicable pipe sizes and materials, and/or in all applicable installation fitting sizes and materials. Please contact GF Piping Systems Japan for JIS K-Factors.
Signet 8150 Flow Totalizer General Compatibility: Signet 515, 525, 2517 Flow Sensors, 3000 Irrigation Sensor Input Frequency Range: 1 to 400 Hz … Flow K – factor 10 11. Total K – factor 11 12. Time Base 12 13. Decimal point placement 13 14. Speed 14 15. Sensitivity 15 16. Troubleshooting 16 17. Flow and Totalizer K – factor selection 16 …
5/18/2016 · In this tutorial will set the Flow rate K – factor for volumetric US Gal and the Total K – factor for mass flow measurement in kgs. Like it is used in weighing …
The k – factor is dependent upon the orifice diameter of the sprinkler – a low k – factor (such as K2.8) restricts the flow of water, while a larger k – factor (such as K22.4, K25.2, or K28.0) permit much more water to flow through. K – factors were originally created to.
Signet 515 and 2536 sensors measure liquid ? ow rates in full pipes and can be used in low pressure systems. The many material choices including PP and PVDF make this model highly versatile and chemically compatible with many liquid process solutions. Sensors can be installed in DN15 to DN900 (½ to 36 in.) pipes using Signet ‘s, Signet Flow Sensors can be installed in up to DN900 (36 in.) pipes using Signet ‘s comprehensive line of custom fittings. These custom fittings, which include tees, saddles, and weldolets, set the sensor to the proper insertion depth into the process flow. The Signet Flow Sensors are also offered in configurations for wet-tap requirements.
7. K – Factors The K – Factor is the number of pulses the sensor will generate for each engineering unit of fluid which passes. They are listed in U.S. gallons and in liters. For example, in a 1 inch PVC pipe, the paddlewheel generates 352.435 pulses per gallon of fluid passing the rotor. K – Factors .
The K factor for sprinklers is NOT the same as a fitting K factor (which is used with a velocity2 element to calculate head loss). Typical sprinkler Discharge Coefficients might be: K =5.6 (where the units are in US gpm/psi 0.5) This equates to a metric K of 80.6 (units are in (l/min)/bar 0.5) or K =8.0 (where the units are in US gpm/psi 0.5), E. Sets totalizer K – factor : 000.01 to 99999. (see technical notes) F. Sets 4 mA setpoint (4 mA and 20 mA setpoints are reversible) G. Sets 20 mA setpoint H. Sets user defined date Technical notes: Flow and totalizer K – factors are independent of each other. These K – factors represent the number of pulses generated by the +GF+ SIGNET flow sensor for